5
Test Functions
5.10

RFID measurement

Access only at MACH4 with RFID read-write unit 13,56 MHz !
That function allows to check the RFID power depending on the position of RFID labels during transport. It is used to
find to best read/write position.
The printout occurs using the heat level and print speed specified in the Setup > Print param. menu.
Notice!
i
The printout of the diagram occurs without taking the label gaps into consideration. This is why endless
media are most suitable for the printout.
Select the RFID power to be used in the menu Setup > Machine param. > RFID power.
Load the label medium to be tested into the printer.
Press the menu button.
Select Test > RFID measurement print menu.
Start the function with the  button.
The printer performs a short label advance and afterwards a number of backfeed steps. The printer measures the
received signal power in every stop position. The message OK appears in the display once the measurement is
complete.
Insert printable medium (labels, endless paper) which extends across the entire printing width.
If the printout is to occur using thermal transfer printing, insert transfer ribbon with the maximum width.
Start the diagram printout with the  button.
1


4
Fig.
19
RFID measurement
1
ID of the tested RFID tag

Signal power

Distance of the measuring position relative to the printing line
Use the position with the best reception in the command E RFID  "Programming Manual"
Setting of the RFID power in the printer configuration
4
5
Manufacturer and memory size of the RFID tag
5
7