17
The cable from the RJ11 port on the EDS controller shall be run through a hole at the back of the machine (A) and
connected to the X10 connection on the CPU card A1.
Insert the cable and mount with the counter nut and cable gland according to the figure.
fig.W01212
Connect the cable from the RJ11 port on the EDS controller to the X10 connection on the CPU card A1.
Strap the cable at suitable positions.
fig.W01212A
On W4400H/W4600H machines with serial number up to –980/1287 and W4850H/W41100H machines with serial
number up to –1220/636, the X10 connection is NOT located at the back of the machine but in the front. In this case,
the X10 connection shall not be used. Instead, it is necessary to install a DMIS kit (the art. No. for the DMIS kit is
988916197).
Install the DMIS kit according to the instructions enclosed with the kit.
When the DMIS kit has been installed, cut the 3-pole X10 connector and strip the three wires approx. 6 mm (1/4
inch). Connect the wires to the terminal (B) enclosed with the DMIS kit.