You can easily check if the machine already has DMIS installed by locating the terminal (B). If terminal (B) is con-
nected; DMIS is installed.
If the machine already has DMIS installed, replace the wires to the terminal (B) with the new. Cut the 3-pole X10 con-
nector and strip the three wires approx. 6 mm (1/4 inch). Connect the wires to the terminal (B) enclosed with the
DMIS kit.

2.6.4 Dual controller

When more pumps are needed it is possible to connect two EDS controllers to the same washer extractor. This
makes it possible to have up to eleven pumps.
Connect one of the EDS controllers to the RS232 port on the I/O module and the other EDS controller to the RS232
port on the CPU module.
fig.W01213
Which pump stand to be used is set in the INSTALLER MENU.