Adjusting The Burner Manifold Gas Pressure - Frymaster 47 Series Service & Parts Manual

Gas fryers
Table of Contents

Advertisement

2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease in removal.
3. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any
obstruction.
4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall tube and bend so that the opening is pointing downward.
1.4 Adjusting Burner Manifold Gas Pressure
This task should be performed by qualified service personnel only.
1. Ensure that the gas valve knob is in the "OFF" position.
2. Remove the pressure tap plug from the gas valve (see arrows in photos below for location).
Non-CE Pilot Ignition Valve
3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
4. Place the gas valve in the "ON" position then place the fryer power switch in the "ON" position.
When the burner lights and continues to burn, note gas pressure reading for correct pressure in
accordance with the accompanying tables.
47 SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
WARNING
Non-CE Electronic Ignition
Valve
1-10
CE Pilot Ignition Valve

Advertisement

Table of Contents
loading

Table of Contents