Checking The Burner Manifold Gas Pressure - Frymaster BIGLA30 Series Service Manual

Lov gas
Hide thumbs Also See for BIGLA30 Series:
Table of Contents

Advertisement

4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall the tube and bend it so that the opening is pointing downward.
1.7

Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole.
4. On non-CE fryers only, place the gas valve in the ON position
5. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for at least
one minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate
table on the following page. The tables list the burner manifold gas pressures for each of the gas types that
can be used with this equipment.
Honeywell
Pressure Tap Plug
Typical Non-CE
Valve Assembly
ON
OFF
Typical CE Valve
Assembly
1-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents