Cleaning Gas Valve Vent Tube; Adjusting Burner Manifold Gas Pressure - Frymaster YSCFC24GSERIES YSCFC24GSERIES Service & Parts Manual

Yscfc24g series flatbottom gas fryers 24/24/15 systems with built-in filtration
Table of Contents

Advertisement

1.3 Cleaning the Gas Valve Vent Tube (if applicable)
1. Set the fryer power switch and the gas valve to the "OFF" position.
2. Carefully unscrew the vent tube from the gas valve.
for ease in removal.
3. Pass a piece of wire through the tube to remove any obstruction. Remove the wire and blow
through the tube to ensure it is clear.
4. Reinstall tube and bend so that the opening is pointing downward.

1.4 Adjusting Burner Manifold Gas Pressure

This task should be performed by qualified service personnel only.
1. Ensure that the gas valve knob is in the
"OFF" position.
2. Remove the pressure tap plug from the
burner manifold.
3. Insert the fitting for a gas pressure-
measuring device into the pressure tap
hole.
4. Place the gas valve in the "ON" position then place the fryer power switch in the "ON" position.
When the burner lights and continues to burn, note gas pressure reading for correct pressure in
accordance with the table on page 1-1.
YSCFC SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
WARNING
The vent tube may be straightened
NOTE:
Remove pressure tap from burner manifold to
check burner manifold pressure.
1-4