Replacing Gas Valve High-Limit Thermostat Wire Adapter; Replacing The Frypot - Frymaster 47 Series Service & Parts Manual

Gas fryers
Table of Contents

Advertisement

1.8.11 Replacing Gas Valve High-Limit Thermostat Wire Adapter

1. Remove the pilot electrical fitting from the gas valve pilot coil.
2. Lift the molded plastic wire adapter assembly and wires out of the pilot coil.
3. Cut the in-line splices from the wire adapter and high-limit thermostat wires.
4. Strip the wire insulation from the end of the high-limit thermostat wires and splice on a new
high-limit thermostat wire adapter assembly.
5. Insert the new molded plastic wire adapter into the gas valve pilot coil.
6. Screw the pilot electrical fitting into the gas valve pilot-coil finger tight, and then 1/8-turn more
with a wrench.

1.8.12 Replacing the Frypot

1. Drain cooking oil/shortening from the frypot.
2. Remove all accessories, e.g., frypot covers, basket lift arms, etc. from the fryer.
3. Disconnect the fryer from gas and electrical supplies.
4. Remove the screws from the top cap above the control panel and lift it up and off the fryer(s).
5. If the fryer is equipped with other than a Thermostat Control, skip to Step 10.
6. Remove the thermostat knob. Remove the screws from the upper left and right corners of the
control panel. Disconnect the control panel from the fryer wiring harness and remove it from the
fryer.
7. Remove the thermostat flexible shaft from the thermostat shaft adjusting screw.
8. Remove the two screws and nuts from the thermostat shaft bracket and lift the thermostat
flexible shaft and bracket out of the component box.
9. Disconnect both wires from the gas valve and the 20-hole terminal block. Skip to Step 14.
10. For fryers equipped with other than thermostat controls, remove the screws from the upper left
and right corners of the control panel. Disconnect the controller from the fryer wiring harness
and remove it from the fryer.
11. Remove the two screws and nuts from the base of the interface board bracket.
12. Disconnect the 12-pin plug from the back of the interface board and remove the temperature
probe and high-limit thermostat wires from the plug using a pin pusher.