Cleaning The Gas Valve Vent Tube; Checking The Burner Manifold Gas Pressure - Frymaster Pro H50-Series Service And Parts Manual

Gas fryers
Table of Contents

Advertisement

3. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and
plug in the electrical cords.
1.3

Cleaning the Gas Valve Vent Tube

1. Set the fryer power switch and the gas valve to the OFF position.
2. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened
for ease of removal.
3. Pass a piece of binding wire (.052 inch diameter) through the tube to remove any obstruction.
4. Remove the wire and blow through the tube to ensure it is clear.
5. Reinstall the tube and bend it so that the opening is pointing down.
1.4

Checking the Burner Manifold Gas Pressure

1. On non-CE fryers only, ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
Typical Non-CE
Valve Assembly
3. Attach a manometer or pressure gauge to the pressure tap hole.
Honeywell
ON
OFF
Pressure Tap Plug
1-5
Typical CE Valve
Assembly