COOLING SYSTEM
INSPECTION
Check the operating temperature of the cooling fan thermo
switch.
• Connect the multi circuit tester to the cooling fan thermo
switch.
• Place the cooling fan thermo switch into a container of oil.
• Heat the oil and check the temperature on the thermometer
when the cooling fan thermo switch is operated.
I T 55L1 09900-25008: Multi circuit tester set
\SMH Cooling fan thermo switch specification
OFF - » O N
ON - » O F F
INSTALLATION
Install the cooling fan thermo switch in the reverse order of
removal. Pay attention to the following points:
• Apply SUZUKI SUPER GREASE "A" to the O-ring.
For USA
99000-25030: SUZUKI SUPER G R E A S E "A"
For the other countries
%£M\99000-25010: SUZUKI SUPER G R E A S E "A"
• Tighten the cooling fan thermo switch to the specified torque.
H
Cooling fan thermo switch: 17 N m (1.7 kgf-m, 12.5 Ib-ft)
A C A U T I O N
* Take special care when handling the cooling fan
thermo switch. Do not subject it to strong blows or
allow it to be dropped.
* Replace the removed O-ring with a new one.
After installing the cooling fan thermo switch, be sure to add
engine coolant. (CU
3
Approximately 88°C (190T)
Approximately 82°C (180T)
2-11)