Flange Back Adjustment - Sony BRC-300 Service Manual

3ccd color video camera / optical multiplex unit
Hide thumbs Also See for BRC-300:
Table of Contents

Advertisement

3-2. BRC-300/300P Camera Block Electrical Alignment

3-2-12. Flange Back Adjustment

The inner focus lens flange back adjustment is carried out
automatically. If the following specified value is not
satisfied, the subject will be out of focus during auto
focusing/manual focusing.
Flange back adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement point
Adjustment remote commander
Measuring instrument
Adjustment page
F
Adjustment addresses
60 to 70
Specification
00 to 0E (address: 6F)
m
. Perform this adjustment after performing "3-2-11. MR
Adjustment".
. Make the lens horizontal and perform this adjustment.
. The data of page: 0, address: 10 must be "00".
. Check that the data of page: 6, address: 02 is "00". If
not, set data: 00 to page: 6, address: 01, and press the
PAUSE button.
Preparation
Check that at both the zoom lens TELE end and WIDE
end, the center of the chart for the flange back adjustment
and center of the exposure screen coincide.
Adjusting procedure
Order Page Address Data Procedure
1
0
01
01
2
6
01
13
3
6
01
15
4
6
02
5
F
6F
3-24
Set the data.
Set the data, and press
PAUSE button.
Set the data, and press
PAUSE button.
Check that the data changes to
"01".
n
The adjustment data will be
automatically input to page: F,
addresses: 60 to 70.
Check the data that the
specification is satisfied.
Settings after adjustment
Order Page Address Data Procedure
1
6
01
00
2
0
01
00
3
4
Flange back adjustment (2)
n
Perform this adjustment after performing "Flange Back
Adjustment (1)".
Subject
Subject more than 500 m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement point
Color monitor
Measuring instrument
Adjustment page
F
Adjustment addresses
60 to 70
m
. Make the lens horizontal and perform this adjustment.
. The data of page: 0, address: 10 must be "00".
. Check that the data of page: 6, address: 02 is "00". If
not, set data: 00 to page: 6, address: 01, and press the
PAUSE button.
Preparation
Set the zoom lens to the TELE end and expose a subject
that is more than 500 m away (subject with clear contrast
such as building, etc.).
n
Nearby subjects less than 500 m away should not be in the
screen.
Set the data, and press
PAUSE button.
Set the data.
Turn off the power and turn on
again.
Perform "Flange Back
Adjustment (2)".
BRC-300/300P
BRU-300/300P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brc-300pBru-300Bru-300p

Table of Contents