13. Remove the camera assembly while slacking off the
flexible flat cable in the arrow direction.
Installation
14. Reattach the camera assembly in the reverse order
from steps 5 to 13.
15. Reassemble the unit in the reverse order from steps 1
to 4.
BRC-300/300P
BRU-300/300P
Camera assembly
Flexible flat cable
2-1-2. Prism Assembly and CD-389S Board
Removing
1. Remove the side rear assembly and side front assem-
bly. (Refer to steps 1 to 3 in Section 1-3-1.)
2. Remove the camera cabinet upper assembly.
(Refer to steps 2 to 5 in Section 1-3-2.)
3. Remove the camera cabinet lower.
(Refer to steps 3 to 5 in Section 1-3-3.)
4. Remove the SE plate.
(Refer to steps 2 to 4 in Section 2-2-9.)
5. Remove the camera assembly.
(Refer to steps 5 to 13 in Section 2-1-1.)
6. Remove the shield chassis.
(Refer to step 6 in Section 2-2-6.)
7. Remove the IF-110 board.
(Refer to steps 7 and 8 in Section 2-2-6.)
8. Remove the DD-208 board.
(Refer to steps 5 and 6 in Section 2-2-4.)
9. Remove the VC-343 board.
(Refer to steps 7 to 10 in Section 2-2-7.)
10. Remove the LED-418 board.
(Refer to steps 3 and 4 in Section 2-2-8.)
11. Remove the three screws, and remove the three heat
sinks from the board chassis.
B2 x 3
Heat sinks
B2 x 3
Heat sink
Voids
Board chassis