Ventilation Of The Spray Booth; Air Line; Material Supply - WAGNER GM 4700AC-H Translation Of The Original Operating Manual

Aircoat spray gun for flat - and round jet nozzles
Hide thumbs Also See for GM 4700AC-H:
Table of Contents

Advertisement

VERSION 09/2011
OPERATING MANUAL
5.1.2

VENTILATION OF THE SPRAY BOOTH

Toxic and/or fl ammable vapor mixtures!
Risk of poisoning and burns
5.1.3

AIR LINE

The use of an air fi lter with air regulator (D) ensures that only dry, clean atomizing air gets
into the spray gun! Dirt and moisture in the atomizing air worsens the spraying quality and
spraying pattern.
5.1.4

MATERIAL SUPPLY

Impurities in the spraying system!
Spray gun blockage, materials harden in the spraying system
Flush the spray gun and paint supply with a suitable cleaning agent.
Bursting hose, bursting threaded joints!
Danger to life from injection of material
ORDER NUMBER DOC
WARNING
Operate the unit in a spray booth approved for the working
materials.
- or -
Operate the unit on an appropriate spraying wall with the
ventilation (suction) switched on.
Observe national and local regulations for the outgoing air
speed.
NOTICE
WARNING
Ensure that the hose material is chemically resistant to the
sprayed materials.
Ensure that the spray gun, threaded joints and material hose
between the unit and the spray gun is suitable for the pressure
generated in the unit.
Ensure that the following information can be seen on the high
pressure hose:
- Manufacturer
- Permissible operating pressure
- Date of manufacture
2311730
GM 4700AC