VERSION 09/2011
OPERATING MANUAL
6.3
CHANGING OR CLEANING FILTER INSERT
1. Decommissioning work and cleaning
2. Relieve the pressure of gun and unit.
3. Secure gun with locking device.
4. Insert fi lter housing (67) into the turning handle, screw in manually with the turning handle and
tighten. Loosen the fi lter housing (67) manually with turning handle (66) and unscrew it. When the
material hose together with fi lter housing and fi lter insert have been exposed, push turning handle
(66) back onto the upper fi lter connection.
5. Pull fi lter insert (64) out of the fi lter housing (67).
6. Thoroughly clean all parts with cleaning agent.
Assembly:
7. Push cleaned or new fi lter insert (64) with opening downwards into fi lter housing (67).
8. Insert fi lter housing (67) into the turning handle, screw in manually with the turning handle and
tighten.
close
open
Procedure
if
connection
diffi cult to loosen:
Loosen fi lter housing (67) with
wrench size B open-end wrench,
supporting the fi lter connection
with SW A open-end wrench.
Spanner A
Spanner B
size 13 mm
size 17 mm
wrench
wrench
0.51 inch
0.67 inch
ORDER NUMBER DOC
B_03649
is
A
B
2311730
64
66
83
67
Note:
Do
connection. The nut may only
be unscrewed by a WAGNER-
Service Station.
GM 4700AC
not
unscrew
fi lter
27