User Manual DEV 2190
5.5.4.4.10.2 .surveillance.fanTable.fanEntry.fanStatus
OID:
Syntax:
Access:
Description:
5.5.4.4.11 .surveillance.internalDeviceStatus
OID:
Syntax:
Access:
Description:
5.5.4.4.12 .surveillance.externalDeviceStatus
OID:
Syntax:
Access:
Description:
5.5.4.4.13 .surveillance.supportHardwareStatus
OID:
Syntax:
Access:
Description:
5.5.4.4.14 .surveillance.errorDescription
OID:
Syntax:
Access:
Description:
.1.3.6.1.4.1.21035.41.3.10.1.2.x
INTEGER {ok (1), notok (2)}
read-only
The status of the related fan, possible values:
"1"
ok: no errors are reported for the fan;
"2"
not ok: an error was detected for the fan.
.1.3.6.1.4.1.21035.41.3.11.0
INTEGER {ok (1), notok (2)}
read-only
The internal device status (e.g. temperature, communication),
possible values:
"1"
ok: no internal device errors are reported;
"2"
not ok: an internal device error was detected.
.1.3.6.1.4.1.21035.41.3.12.0
INTEGER {ok (1), notok (2), notapplicable (3)}
read-only
The status of external devices, e.g. of an antenna controller.
There are no external devices available for the DEV 2190, thus
"3" (notapplicable) is returned.
.1.3.6.1.4.1.21035.41.3.13.0
INTEGER {ok (1), notok (2), notapplicable (3)}
read-only
The status of supporting hardware, e.g. of a digital interface
module. In this application .supportHardwareStatus is mapped to
the surveillance of the fan & monitoring module, i.e.
"1"
ok: no fan & monitoring module error is reported;
"2"
not ok: a fan & monitoring module error was detected;
"3"
not applicable: is not returned for this type of device.
.1.3.6.1.4.1.21035.41.3.14.0
OCTET STRING (SIZE(1..48))
accessible-for-notify
.errorDescription contains the latest error description string, which
is used for .trapAlarmText; please refer to chapter 5.5.4.1.1.
Copyright DEV Systemtechnik GmbH 2009-2017
91