User Manual DEV 2190
5.5.4.3
.application
5.5.4.3.1 .application.controlMode
OID:
Syntax:
Access:
Description:
Note:
The value "3" (Auto Mode) is available for devices with installed redundancy
switching functionality, only.
Via the SNMP setup of the Web Interface (please refer to chapter 5.4.7.2.2)
.controlMode can be set to read-write (default) or to read-only.
The factory setting is "2" (Remote Mode).
.1.3.6.1.4.1.21035.41.2.1.0
INTEGER {local (1), remote (2), auto (3)}
read-write OR read-only
The device operation mode (chapter 5.1), possible values:
"1"
Local Mode: local operation at the device or via Web I/F;
"2"
Remote Mode: remote operation via SNMP;
"3"
Auto Mode: autonomous switching.
Copyright DEV Systemtechnik GmbH 2009-2017
73