Maximum Power Available For 3.5-Kw Inputs (Dc) - Cisco Nexus 7706 Hardware Installation Manual

Nexus 7000 series
Hide thumbs Also See for Nexus 7706:
Table of Contents

Advertisement

Maximum Power Available for 3.5-kW Inputs (DC)

Power Inputs
1 input (277 V)
1 input (220/230
V)
1 input (210 V)
1 input (110 V)
Note
A combination of 3-kW AC and 3.5-kW HVAC/HVDC power supplies can be used.
Maximum Power Available for 3.5-kW Inputs (DC)
The maximum power available for operations depends on the input power from your power source, the number
and output capabilities of your power supplies, and the power redundancy mode that you use. The following
table lists the amount of power available for 3.5-kW HVAC/HVDC power supplies depending on DC power
inputs, number of power supplies, and the mode used.
Cisco Nexus 7706 Hardware Installation Guide
76
Power Supplies
Combined Mode
1
3500 W
2
7000 W
3
10,500 W
4
14,000 W
1
3500 W
2
7000 W
3
10,500 W
4
14,000 W
1
3100 W
2
6200 W
3
9300 W
4
12,400 W
1
1500 W
2
3000 W
3
4500 W
4
6000 W
Power Supply
Input Source
Redundancy
Redundancy
Mode
Mode
3500 W
3500 W
7000 W
3500 W
10,500 W
7000 W
3500 W
3500 W
7000 W
3500 W
10,500 W
7000 W
3100 W
3100 W
6200 W
3100 W
9300 W
6200 W
1500 W
1500 W
3000 W
1500 W
4500 W
3000 W
Managing the Switch
Full Redundancy
Mode
3500 W
3500 W
7000 W
3500 W
3500 W
7000 W
3100 W
3100 W
6200 W
1500 W
1500 W
3000 W
OL-31330-01

Advertisement

Table of Contents
loading

Table of Contents