LEDs
LED
Status
Link (for
each port)
OL-31330-01
Color
Status
Green
All diagnostics passed. This module is operational (normal
initialization sequence).
Amber
Indicates one of the following:
• The module is booting or running diagnostics.
• An overtemperature condition has occurred. (A minor
Flashing red
Indicates one of the following:
• The switch has just been powered on, and the module is resetting.
• The module has been inserted during the initialization process.
• An overtemperature condition has occurred. A major temperature
• The module has failed to download code and configuration
Red
Indicates one of the following:
• The module has detected a slot ID parity error and will not power
• The module is not fully inserted, and it is not making a reliable
Off
The module is not receiving power.
The port is active (the link is connected and active).
Green
Amber
The module or port is disabled by using a CLI command or the
module is initializing.
Flashing amber
The port is faulty and disabled.
Off
The port is not active or the link is not connected.
temperature threshold has been exceeded during environmental
monitoring.)
threshold has been exceeded during environmental monitoring
information successfully during the initial reset. The module is
not online.
on or boot up.
connection with the supervisor.