2 Mechanical Installation

2
Mechanical Installation
Upon Receipt
Perform the following tasks after receiving the drive:
• Inspect the drive for damage. If the drive appears damaged upon receipt, contact your supplier.
• Verify receipt of the correct model by checking the information on the nameplate. If you have received the wrong
model, contact your supplier.
Installation Environment
For optimum performance life of the drive, install the drive in an environment that meets the conditions listed below.
Environment
Installation Area
Ambient Temperature
Humidity
Storage Temperature
Surrounding Area
Altitude
Vibration
Orientation
Installation Orientation and Spacing
Always install the drive in an upright position. Leave space around
the unit for proper cooling as shown in the figure on the right.
Degree of Protection
The degree of protection of L1000A drives is IP20. Install the drive in a cabinet if higher degree of protection is required.
8
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
Indoors
–10 to +50°C
Drive reliability improves in environments without wide temperature fluctuations.
When using the drive in an enclosure panel, install a cooling fan or air conditioner in the area to ensure that the air
temperature inside the enclosure does not exceed the specified levels.
Do not allow ice to develop on the drive.
95% RH or less and free of condensation
–20 to +60°C
Install the drive in an area free from:
• oil mist and dust
• metal shavings, oil, water or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight
1000 m or lower, up to 3000 m with derating (for details refer to the Technical Manual)
10 to 20 Hz at 9.8 m/s
2
20 to 55 Hz at 5.9 m/s
2
Install the drive vertically to maintain maximum cooling effects.
YASKAWA ELECTRIC TOEP C710616 33A YASKAWA AC Drive L1000A Quick Start Guide
Conditions
50 mm
30 mm
30 mm
50 mm
120 mm
Air
120 mm

Hide quick links: