YASKAWA CIMR-LC2A0018 Quick Start Manual page 15

L1000a series ac drive for elevator applications
Table of Contents

Advertisement

Control Circuit Terminal Functions
Type
Digital Inputs
Digital Input
Power Supply
Safe Disable
Inputs
Analog Inputs
Fault Relay
Multi-Function
Relay Output
Multi-Function
Photocoupler
Output
Monitor Output
Safety Monitor
Output
NOTICE: The terminals HC, H1, H2 are used for the Safe Disable function. Safe Disable can be used to enable/disable the drive. If
special requirement are fulfilled, it can also be utilized for reducing the number of motor contactors to one. Refer to
Function on page 41
NOTICE: The wiring length to terminals HC, H1 and H2 should not exceed 30 m.
NOTICE: When connecting a reactive load such as a relay coil to a photo coupler output, attach a flywheel diode to the load (relay coil)
like shown below. Ensure the diode rating is greater than the circuit voltage.
YASKAWA ELECTRIC TOEP C710616 33A YASKAWA AC Drive L1000A Quick Start Guide
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
No.
Terminal Name (Function)
Up Command (Closed: Up, Open: Stop)
S1
Down Command (Closed: Down, Open: Stop)
S2
Multi-function input 3 (Nominal Speed)
S3
S4
Multi-function input 4 (Inspection Operation)
Multi-function input 5 (Intermediate Speed 1)
S5
Multi-function input 6 (Leveling Speed)
S6
Multi-function input 7 (Not used)
S7
Multi-function input 8 (Not used)
S8
Multi-function input common
SC
SN
0 V
SP
+24 Vdc
Safe Disable input 1
H1
Safe Disable input 2
H2
Safe Disable function common
HC
Power supply for analog inputs
+V
Power supply for analog inputs
–V
A1
Multi-function analog input 1 (Speed Reference Bias) –10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
Multi-function analog input 2 (Not used)
A2
Analog Input common
AC
E (G) Ground for shielded lines and option cards
MA N.O. output
MB N.C. output
MC Fault output common
M1
Relay output 1 (Brake Control)
M2
M3
Relay output 2 (Output Contactor Control)
M4
M5
Relay output 3 (Drive Ready)
M6
P1
Photocoupler output 1 (During frequency output 2)
C1
P2
Photocoupler output 2 (Not used)
C2
Analog monitor output 1 (Output speed)
FM
AM Analog monitor output 2 (Output current)
Monitor common
AC
DM+ Safety monitor output
DM– Safety monitor output common
for details. Always remove the wire link between HC, H1, or H2 when using Safe Disable.
Supply (max 48 V)
Photocoupler
24 Vdc, 8 mA
Use the wire link between terminals SC and SN or between SC and
SP to select sinking or sourcing, and to select the power supply.
Photocoupler, 24 Vdc, 8 mA
Use the wire link between terminals SC and SN or between SC and
SP to select sinking or sourcing, and to select the power supply.
24 Vdc, 8 mA
One or both open: Drive output disabled
Both closed: Normal operation
Internal impedance: 3.3 kΩ
Off time of at least 1 ms
Set the S3 jumper to select sinking or sourcing, and to select the
power supply.
Common for the Safe Disable function
10.5 Vdc (max. allowable current 20 mA)
–10.5 Vdc (max. allowable current 20 mA)
–10 to 10 Vdc, 0 to 10 Vdc (input impedance: 20 kΩ)
0 V
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA
Photocoupler output 48 Vdc, 2 to 50 mA
–10 to +10 Vdc, 0 to +10 Vdc
0 V
Outputs status of Safe Disable function. Closed when both Safe
Disable channels are closed. Up to +48 Vdc 50 mA.
Flywheel diode
DC Power
Reactive
I (max 50 mA)
load
3 Electrical Installation
Function (Signal Level) Default Setting
Safe Disable Input
15