EBARA MR Use And Maintenance Manual page 7

Circulating pumps
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
CONTENT
1.
GENERAL ..................................................................................................................................................................7
1.1
INTENDED USE ...............................................................................................................................................7
1.2
TECHNICAL DATA ...........................................................................................................................................7
1.2.1 IDENTIFICATION CODE ..................................................................................................................................7
1.2.2 TECHNICAL SPECIFICATIONS OF THE PUMP .............................................................................................7
1.2.3 TYPES OF FLUIDS ..........................................................................................................................................8
2.
PYCTOGRAMS..........................................................................................................................................................8
2.1
HAZARD SYMBOLS ........................................................................................................................................8
2.2
STAFF QUALIFICATION ..................................................................................................................................8
2.3
FAILURE TO COMPLY WITH SAFETY INSTRUCTIONS ................................................................................8
2.4
SAFETY INSTRUCTIONS FOR THE USER ....................................................................................................8
2.5
CHECK AND INSTALLATION...........................................................................................................................8
2.6
REPLACEMENT AND SPARE PARTS .............................................................................................................8
2.7
UNINTENDED USE ..........................................................................................................................................8
3.
TRANSPORT AND STORAGE .................................................................................................................................8
4.
PRODUCT DESCRIPTION ........................................................................................................................................8
4.1
PUMP DESCRIPTION ......................................................................................................................................8
5.
ASSEMBLY ................................................................................................................................................................9
5.1
PUMP ASSEMBLY ...........................................................................................................................................9
5.1.1 ISOLATING THE PUMP FROM COOLING DEVICES / AIR CONDITIONING SYSTEMS ...............................9
5.2
WIRING ............................................................................................................................................................9
5.2.1 CONNECTION TO THE MAINS .....................................................................................................................10
6.
PUMP START-UP ....................................................................................................................................................10
6.1
FILLIG AND AIR REMOVAL ...........................................................................................................................10
6.2
PUMP SPEED ADJUSTMENT .......................................................................................................................10
7.
MAINTENANCE / MAINTENANCE WORKS ..........................................................................................................11
8.
TROUBLESHOOTING ............................................................................................................................................. 11
9.
DECLARATION OF CONFORMITY ........................................................................................................................ 11
1. GENERAL
1.1 INTENDED USE
The pumps of MR F series is used for conveying fluids in heating, cooling, air conditioning and ventilation systems.
1.2 TECHNICAL DATA
1.2.1 IDENTIFICATION CODE
MR
(B)
(D)
1.2.2 PUMP ELECTRICAL SPECIFICATIONS
- ingress protection rating IP 44
- insulation class H
- the motor is protected in series with Klixon
- sound pressure level <70 dB(A)
- fluid temperature from -10°C to +120°C.
- maximum ambient temperature 40°C
- maximum allowed pressure within the system is 1 MPa (10 bar).
40
120
Maximum Pressure (in dm)
Nominal diameter of the pump
Twin impeller pump
Pump body in bronze
Model
EN
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr bMr fMr m

Table of Contents