Features and functions
Control voltage/current consumption
for control inputs
Status signals
(output signals)
Voltage output
Analogue output (option)
Analogue input (option)
SAR 16.2 Control unit - electromechanical
Standard:
24 V DC, current consumption: approx. 10 mA per input
Options:
48 V DC, current consumption: approx. 7 mA per input
60 V DC, current consumption: approx. 9 mA per input
115 V DC, current consumption: approx. 15 mA per input
100
120 V AC, current consumption : approx. 15 mA per input
All input signals must be supplied with the same potential.
Standard:
6 programmable output contacts:
-
5 potential-free NO contacts with one common, max. 250 V AC, 1 A (resistive
load)
Default configuration: End position CLOSED, end position OPEN, selector switch
REMOTE, SIL function active, SIL fault, torque fault CLOSE, torque fault OPEN
-
1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load)
Default configuration: Collective fault signal (torque fault, phase failure, motor
protection tripped)
Analogue output signal for position feedback
-
Galvanically isolated position feedback 0/4
Options:
6 programmable output contacts:
-
5 change-over contacts with one common, max. 250 V AC, 1 A (resistive load),
1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load)
12 programmable output contacts:
-
10 potential-free NO contacts, 5 with one common each, max. 250 V AC, 1 A
(resistive load), 2 potential-free change-over contacts, max. 250 V AC, 5 A (resistive
load)
6 programmable output contacts:
-
6 potential-free change-over contacts without one common, per contact max. 250
V AC, 5 A (resistive load)
10 programmable output contacts:
-
10 potential-free change-over contacts without one common, per contact max.
250 V AC, 5 A (resistive load)
6 programmable output contacts:
-
4 mains failure proof potential-free NO contacts with one common, max. 250 V
AC, 1 A (resistive load), 1 potential-free NO contact, max. 250 V AC, 1 A (resistive
load), 1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load)
6 programmable output contacts:
-
4 mains failure proof potential-free NO contacts, max. 250 V AC, 5 A (resistive
load), 2 potential-free change-over contacts, max. 250 V AC, 5 A (resistive load),
12 programmable output contacts:
-
8 mains failure proof potential-free NO contacts, max. 250 V AC, 1 A (resistive
load), 2 potential-free NO contacts, max. 250 V AC, 1 A (resistive load), 2 potential-
free change-over contacts, max. 250 V AC, 5 A (resistive load)
12 programmable output contacts:
-
8 mains failure proof potential-free NO contacts, max. 250 V AC, 5 A (resistive
load), 4 potential-free change-over contacts, max. 250 V AC, 5 A (resistive load),
All output signals must be supplied with the same potential.
Standard:
Auxiliary voltage 24 V DC: max. 100 mA for supply of control inputs, galvanically isolated
from internal voltage supply.
Option:
Auxiliary voltage 115 V AC: max. 30 mA for supply of control inputs, galvanically isolated
from internal voltage supply
(Not possible in combination with PTC tripping device)
2 analogue outputs:
With position transmitter option: Output of travel and torque as continuous values between 0/4 and 20
mA
2 analogue inputs:
With positioner/process controller option: Input of actual position value/actual process value as continuous
values between 0/4 and 20 mA
Technical data
20 mA (load max. 500 Ω)