Dwells / Delays; Delay Apply; Save Set Up; Recall Set Up - ID Technology 250 Operator / Technical Manual

Print and apply
Table of Contents

Advertisement

Save Set-up
1. 1–
2. 2 –
3. 3 –
4. Factory –
Recall Set-up
1. 1 –
2. 2 –
3. 3 –
4. Factory –

Dwells / Delays

1.
Delay Apply – This is the time from when the product detector senses the
product to the time the application process begins. This setting is useful in
determining the placement of the label on the product. Manually moving the
product detector is the rough or course adjustment, changing the setting of
the "Delay Apply" is the fine adjustment. Increasing the time in the menu will
increase the delay of the trigger to the applicator. This increase in time will
effectively move the placement of the label back on the product, or further
toward the back edge. Decreasing the setting of the delay apply will cause
the applicator to be triggered faster after the product detector senses the
product. This effectively moves the label toward the front of the product.
2.
Dwell Blast – [Not used in the tamp mode] This is the time that the valve on
the pneumatics module will stay open allowing air to be exhausted through
the 1.) tamp pad (on tamp-jet only) or 2.) the label grid (on blow on only)
3.
Delay Air Assist – Using this setting/toggle, you can regulate how long the
air to the air assist tube stays energized. Very effective when you are using
a long label and need assistance getting the label out onto the tamp pad
and laying flat. Increasing the value makes the air assist air stay on longer;
while decreasing the value shortens the time the air is sent through the air
assist tube.
Operators/Technical Manual
Saves the set-up you selected in this session
to one of the three buffers listed. Annotate the
saved set-up in the front of your manual on the
table provided. Enter the parameter set with
either an "X" or the numeric value used.
Recalls the set-up you selected in this session
to one of the three buffers listed. Annotate the
saved set-up in the front of your manual on the
table provided. Enter the parameter set with
either an "X" or the numeric value used.