Component Resistance Chart; Water Fill Height 3 ± .5; Electrical Requirements; Incoming Water Pressure - Electrolux GOOD Service Manual

3.0 cu. ft. horizontal axis washer
Table of Contents

Advertisement

QUICK REFERENCE SHEET

Component resistance chart.

Good Models
Water fill height 3 ± .5 "
No load, start position of permanent press cycle.
Better Models
Water fill height dependent upon selected cycle.

Electrical requirements.

Incoming water pressure.

Drain requirements.

Motor.

Tub Pulley to Motor Pulley Ratio.

Tub Capacity.

Automatic Temperature Control Specifications. (Better Models).
Regulated hot wash temperature
Regulated warm wash and rinse temperature
Regulated cold wash and rinse temperature
Electrical component
Dispenser valve solenoids
Door lock solenoid
Pump motor
NTC Thermistor
M1 TO M2
M2 TO M3
Motor
M1 TO M3
M4 TO M5
Circuit - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse
or circuit breaker.
30 and 120 pounds per square inch (maximum
unbalance pressure, hot vs. cold, 10 psi.)
Drain capable of eliminating 17 gals (64.3 L) per minute.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
The standpipe height above the floor should be:
Minimum height:
Maximum height:
No load agitate wattage - Max 150
No load spin wattage - Max 550
16 TO 1
3.0 cu. ft.
130° ± 7° F
90° ± 7° F
65° ± 7° F
9
Resistance Ω
@ 77° F (25°C)
800 ± 7%
1325 ± 10%
12 ± 7%
50K ± 2%
5.3 ± 7%
5.3 ± 7%
5.3 ± 7%
118 ± 7%
24 in. (61 cm)
96 in. (244 cm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Better

Table of Contents