Troubleshooting; Oib - Cisco GS7000 Installation And Operation Manual

Super high output intelligent node
Table of Contents

Advertisement

Troubleshooting

This troubleshooting section lists common problems and their solutions. If a troubleshooting procedure
directs you to replace a module of the node, see

OIB

There are 3 LEDs on the OIB, Heartbeat LED, Communication LED, and Power LED.
Condition
Normal
Power supply
fault
Error #1
Error #2
Error #3
OIB, page 47
Troubleshooting the node, page 48
Power
Heartbeat LED
LED
On
Steady blink
Off
Off
On
Not blink
On
Steady blink
On
Not blink
Cisco GS7000 Super High Output Intelligent Node Installation and Operation Guide
C H A P T E R
Removing and Replacing Modules, on page
Communication
LED
Steady blink
Normal behavior
Off
Check power supply and power supply
voltages. Check cabling and that the
appropriate power shunts are installed in the
launch amplifier.
Not blink
If Heartbeat LED and Communication LED
blink on power up and then stay off, problem
is with boot. Can be a device failure or
software is not loaded. Try cycling power.
Not blink
OS is ok but node control software is not
running or is stuck. If this condition persists
for more than a minute or two after power
up, check all the cables connecting the lid
and launch amplifier. Try cycling power.
Steady blink
This condition should not be possible unless
Heartbeat LED is damaged.
6
39.
47

Advertisement

Table of Contents
loading

Table of Contents