Equipotential Bonding

Caution
RF connectors and housing seizure assemblies can be damaged if shunts are not removed from the
equipment before installing or removing modules from the housing.
Equipotential Bonding
If this equipment is equipped with an external chassis terminal marked with the IEC 60417-5020 chassis icon
(
equipotential bonding connection instructions.
Shock Hazard - Housing/Enclosure of the unit must be reliably bonded to protective earth/ground conductor
prior to connecting the unit to a power source.
Do not touch internal conductor of F/COAX connector or coax cable while the node is energized and
disconnect power before removing cover because 90 V a.c. can be accessible.
Equipment connected to the protective earthing of the building installation through the mains connection
or through other equipment with a connection to protective earthing – and to a cable distribution system using
coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has
therefore to be provided through a device providing electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11).
In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic
Note
isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength
of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also be accepted in Norway):
Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet
et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV
nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.
Translation to Swedish:
Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt
är kopplad till kabel-TV nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning
av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.
Cisco GS7000 Super High Output Intelligent Node Installation and Operation Guide
xii
), the installer should refer to CENELEC standard EN 50083-1 or IEC standard IEC 60728-11 for correct