3.3.4. Note for the developing shutter installation work
(1) Symptom
Following is the important points to fit the shutter to the developing unit at service visit.
If it is not installed correctly, the shutter does not close completely and the toner may spill. Make
sure to install correctly and check it slides smoothly.
(2) Solution How to install developing shutter
1. Remove the tape
spring
2. Clean the toner outlet
3. Attach the spring
spring
KONICA MINOLTA Confidential
tape
shutter
- 187 -