Konica Minolta AccurioPress C2070 Troubleshooting Manual page 142

Hide thumbs Also See for AccurioPress C2070:
Table of Contents

Advertisement

Direction (b)
1.
Change paper condition
Dehumidify the paper or set the paper upside down in the paper cassette.
2.
Adjust the discharge needle position
1.
Remove the separate discharging plate unit.
2.
Remove the position adjustment pings set inside of the both sides of 2
3.
Reinstall the pins using the lower hole
4.
Reinstall the separate discharging plate unit.
3.
Replace the separate discharging plate unit.
Remove the separate discharging plate unit from the 2
Install the new one.
Note:
When the paper type, paper weight and the ambient condition changes, return the
discharge needle position to the center.
Separate
unit
Remove from 2
KONICA MINOLTA Confidential
discharging
nd
transfer unit.
図 2.2 次転写ユニット概要図
- 141 -
nd
transfer unit.
plate
Discharge needle
position adjustment
location
When the discharge
needle assy is removed,
Pins as shown in Fig 2 can
be seen.
nd
transfer unit.
Feed
direction

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents