Static Tags Ssi_Absolute_Encoder - Siemens SIMATIC ST-1500 Function Manual

Table of Contents

Advertisement

4.5.7

Static tags SSI_Absolute_Encoder

Tag
NewReferenceValue0
NewReferenceValue1
NewReferenceValue0_M
NewReferenceValue1_M
CurReferenceValue0
CurReferenceValue1
CurReferenceValue0_M
CurReferenceValue1_M
AdditionalErrorID
UserCmdFlags
SetReferenceValue0
SetReferenceValue1
SetDQ0
SetDQ1
ManualCtrlDQ0
ManualCtrlDQ1
UserStatusFlags
StatusDI0
StatusDI1
StatusDQ0
StatusDQ1
The instruction sets the TM_CTRL_DQm bit to FALSE. in the control interface of the module. The static tag SetDQm
1
acts on the control bit SET_DQm.
Counting, measurement and position detection
Function Manual, 12/2017, A5E32009889-AG
Data type
Default
DINT
L#0
DINT
L#10
REAL
L#0.0
REAL
L#10.0
DINT
L#0
DINT
L#10
REAL
L#0.0
REAL
L#10.0
DWORD
W#16#0000
STRUCT
-
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
STRUCT
-
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
Using the SSI_Absolute_Encoder technology object
4.5 Programming the SSI_Absolute_Encoder
Access
Description
Write
New comparison value 0 in operating mode
"Use position value (SSI absolute value) as
reference"
Write
New comparison value 1 in operating mode
"Use position value (SSI absolute value) as
reference"
Write
New comparison value 0 in operating mode
"Use measured value as reference"
Write
New comparison value 1 in operating mode
"Use measured value as reference"
Read
Current comparison value 0 in operating mode
"Use position value (SSI absolute value) as
reference"
Read
Current comparison value 1 in operating mode
"Use position value (SSI absolute value) as
reference"
Read
Current comparison value 0 in operating mode
"Use measured value as reference"
Read
Current comparison value 1 in operating mode
"Use measured value as reference"
Read
Error information of an internal instruction,
e.g.,RDREC
Write
Set comparison value 0
Write
Set comparison value 1
Write
Set digital output DQ0
Write
Set digital output DQ1
Write
Enable setting of digital output DQ0.
TRUE: SetDQ0 sets DQ0
FALSE: Setting not enabled
Write
Enable setting of digital output DQ1:
TRUE: SetDQ1 sets DQ1
FALSE: Setting not enabled
Read
Current status of digital input DI0
Read
Current status of digital input DI1
Read
Current status of digital output DQ0
Read
Current status of digital output DQ1
1
1
165

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: