Using the SSI_Absolute_Encoder technology object
4.5 Programming the SSI_Absolute_Encoder
4.5.5

Output parameter SSI_Absolute_Encoder

Parameter
Declaration
StatusHW
OUTPUT
StatusUp
OUTPUT
StatusDown
OUTPUT
CompResult0
OUTPUT
CompResult1
OUTPUT
CaptureStatus OUTPUT
ZeroStatus
OUTPUT
PosOverflow
OUTPUT
NegOverflow
OUTPUT
Error
OUTPUT
ErrorID
OUTPUT
PositionValue
OUTPUT
Captured-
OUTPUT
Value
162
Data
Default
type
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
BOOL
FALSE
WORD
0
DINT
0
DINT
0
Description
Status bit technology module: The module is configured and
ready for operation. The module data is valid.
Status bit: Last position value has changed in the positive direc-
tion and took place no more than 0.5 s ago.
Status bit: Last position value has changed in the negative direc-
tion and took place no more than 0.5 s ago.
Status bit: Comparison event for DQ0 (change of state) occurs
as a result of the selected comparison condition.
The positive edge of the input parameter EventAck is used to
reset CompResult0 .
Status bit: Comparison event for DQ1 (change of state) occurs
as a result of the selected comparison condition.
The positive edge of the input parameter EventAck is used to
reset CompResult1 .
Status bit: Capture event occurred, the output parameter Cap-
turedValue has a valid Capture value
If the input parameter CaptureEnable is set, the configured edge
sets the status bit CaptureStatus. at the respective digital input.
You reset CaptureStatus using the negative edge of the input
parameter CaptureEnable .
Status bit: PositionValue has reached or exceeded the value "0"
irrespective of the count direction.
You reset ZeroStatus using the positive edge of the input param-
eter EventAck.
Status bit: PositionValue has exceeded the high limit of the posi-
tion value range of the encoder in the positive direction.
You reset PosOverflow using the positive edge of the input pa-
rameter EventAck.
Status bit: PositionValue has exceeded the low limit of the posi-
tion value range of the encoder in the negative direction.
You reset NegOverflow using the positive edge of the input pa-
rameter EventAck.
An error has occurred. Refer to the output parameter ErrorID for
the cause of the error.
The ErrorID (Page 164) parameter displays the number of the
error message.
ErrorID = 0000
: There is no error.
H
Current position value
The last acquired Capture value The value is retained until the
next Capture event, irrespective of the input parameter Cap-
tureEnable.
If a new Capture event has occurred, CaptureStatus is set and is
reset by you using the negative edge of the input parameter
CaptureEnable .
Counting, measurement and position detection