Banner SureCross DX80 Gateway Network Manual page 13

Wireless i/o
Hide thumbs Also See for SureCross DX80 Gateway:
Table of Contents

Advertisement

SureCross Wireless I/O Network Manual
Single-click Button 1 to advance through menu
*
RUN
*
DINFO
*
FCTRY
Factory Info
Device Info
AUTO
AUTO
adjust the rotary
DISPLAY
DISPLAY
switches to survey
LOOP
LOOP
the selected Node
Single-click
Single-click
Single-click
Single-click
Button 1
Button 1
Button 1
Button 1
(DEV)
NID XX
NID XX
GATEWY
GATEWY
(DEV)
(DEV)
(NAME)
(RADIO
GATEWY
GATEWY
XXXXXX
MICRO)
I/O XX
I/O XX
XXXXXX
V 00.0 A
ON/OFF
ON/OFF
XXXXXX
(NID)
MICRO)
XX
V 00.0 A
(SLID)
XX
(BAUD)
XX
(PRTY)
MODEL)
XX
(0000-00)
(PROD
DX80 Node Set-up Menu
When power is applied, the DX80 begins running. The display screen auto loops through the RUN menu and communication begins
between the Gateway and Node(s). Auto looping through the RUN menu is the normal operating mode for all devices on the wireless
network.
From the RUN Menu (or any menu), single-click button 1 to advance through the top-level menus. The device auto display loops through
the menu options if either of the RUN, DINFO, or FCTRY menus are selected. If the device is paused on the DVCFG or DERR menu
options, the display does not auto display loop.
To enter manual scrolling mode, double-click button 2 at the top level menu. Use the instructions shown in the chart below to navigate the
menu system. To return to the top level menus and auto display loop mode, double-click button 2 twice.
Node LCD Timeout: After 15 minutes of inactivity, the LCD screen stops displaying information. Press any button to refresh the display if
the Node has entered this energy-saving mode.
The * before the menu name indicates a top-level menu option. The () indicate submenu items.
When using Rotary Dial Addressing Mode, use the rotary dials to set the Network ID (NID) and Device ID (NADR) at any time. The left
rotary dial sets the Network ID and the right rotary dial sets the Node Address. Once changed, allow five seconds for the devices to
update to the new Network ID.
rev. I
*
SITE
*
DVCFG
Site Survey
Device Config
Single-click
Single-click
Button 2
Button 2
AUTO
DISPLAY
LOOP
adjust right rotary
switch to survey the
selected Node
(DEV)
NOD XX
Single-click
Button 2
AUTO
DISPLAY
LOOP
M XX
(NID)
R XX
Network ID
(LCD
Single-click
Y XX
Button 2
G XX
Double-click
Button 2
adjust rotary switches
(DX80
to set the network ID
S/N)
CUR XX
(0000)
NEW XX
(DX80
Single-click
Button 2
SAVES NEW
VALUES
DATE)
(00-00)
www.bannerengineering.com - tel: 763-544-3164
*
DERR
Device Error
New Error
*
ERROR
Detected
Single-click
Button 2
Single-click
Button 2
Single-click Button 1 to advance through menu
NOD XX
EC XX
CLEAR
DISABL
IGNORE
Single-click
Single-click
Single-click
Button 2
Button 2
Button 2
ERR
ERR
ERASED
DISABL
Next
Single-click
Single-click
Button 2
Button 2
Device
Single-click Button 1 to advance through menu
(SLID)
(BAUD)
(PRTY)
Slave ID
Baud Rate
Parity
Single-click
Single-click
Single-click
Button 2
Button 2
Button 2
9600
None
adjust rotary switches
Even
to set slave ID, using
19200
button 1 to select the
digits
38400
Odd
CUR XX
Single-click
Single-click
Button 2
Button 2
NEW XX
Single-click
Button 2
SAVES
SAVES
DISPLAYED
DISPLAYED
VALUE
VALUE
SAVES NEW
VALUES
* Set to 000000 to use the serial number.
(XADR)
(MAXN)
Timing
Extended Addressing
Single-click
Single-click
Button 2
Button 2
Single-click
AUTO
AUTO
8
Button 2
16
NETWRK
MANUAL
32
BINDNG
Single-click
Single-click
48
Button 2
Button 1 or 2
Single-click
Button 2
SET
Reboot
XADR
SAVES
DISPLAYED
ADJUST ROTARY
VALUE
SWITCH TO
SET XADR
*
XXXXXX
Single-click
Button 2
CONFRM
XADR
XXXXX
Single-click
Button 2
SAVED
13