SECTION 4
Functions

Communications Specifications

With the FL Remote ID, communications with the RF Tags is determined by the operating mode set on the
mode switch, the command selected, and the options selected to execute the command.
Operating mode
There are four operating modes.
For the mode settings, refer to Part Names and Functions in Section 1.
■ Trigger Mode
When the RF Tag on a workpiece or palette moves within the communications range of the Antenna, it
is detected by a sensor or a switch. A control signal (trigger signal) is output from the PLC to the FL
Remote ID, which triggers the FL Remote ID to begin communications with the RF Tag. The FL
Remote ID reads the RF Tag data and outputs the results to the PLC.
FL Remote
Master Unit
■ Auto Mode
When the RF Tag of a workpiece or palette is within the communications range of the Antenna, the
Remote ID automatically begins communications with the RF Tag and outputs the result to the PLC.
RFID System
46
User's Manual
p.13
FL Remote ID
V680-HAM42-FRT
FL Remote
Master Unit
RF Tag
V680-D1KP66T-SP
Antenna
V680-HS63-SP
FL Remote ID
V680-HAM42-FRT
Antenna
V680-HS63-SP
Palette, etc.
Sensor or Switch
RF Tag
V680-D1KP66T-SP
Palette, etc.