Noise Measurement - Omron V680-HS63 User Manual

V680 series, fl remote id, antenna, rf tag
Hide thumbs Also See for V680-HS63:
Table of Contents

Advertisement

SECTION 4
Functions

Noise Measurement

You can check whether noise that affects communications with RF Tags exists in the surroundings where the
Antenna and Reader/Writer are installed.
When a noise measurement command is sent from the PLC, the noise strength received by the Antenna is
output in a value from 00 to 63.
To start in Noise Level Measurement Mode, set the mode switch to 3, and then start the Unit. The noise
strength will be displayed in five levels on the data display. It can be checked directly from the FL Remote ID.
Refer to NOISE MEASUREMENT for details of the noise measurement command.
p.66
Relationship between Result Output and Display
Result output
00 to 09
20 to 29
40 to 99
Note: The result is output as a decimal value.
Example of Effect on Result Output and Communications
Range (Reference Data)
RFID System
52
User's Manual
DATA display status
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
(%)
100
90
80
70
60
50
40
30
20
10
0
20
40
Noise level
Result Output
DATA display status
7
10 to 19
3
7
30 to 39
3
Read
Write
60
80
100
6
5
4
2
1
0
6
5
4
2
1
0

Hide quick links: