Control Circuit Plug Connectors For Supply Modules; Quick Connector For D8T Module - ABB ACS880-304 +A018 Hardware Manual

Diode supply modules
Table of Contents

Advertisement

188 Ordering information

Control circuit plug connectors for supply modules

The control circuit plug connectors are not included in the module kit but you must order
them separately:
You need one plug connector X50 for the AC auxiliary power supply connection for
each diode supply module. See the table below.
If you supply 24 V DC for the control unit from one diode supply module, you need one
plug connector X53.
For more information on the plug connectors, see section
the diode supply module
Connector
X50
4 mm
MSTB 2.5/5-ST-5.08
X53

Quick connector for D8T module

The module quick connector is not included in the diode supply module kit but you must
order it separately for each D8T supply module. The AC power input is connected to the
module through the quick connector.
For the dimension drawing, see section
page 242.
Module size
Enclosure width
D8T
on page 105.
Data
STV S 9 SB
9-pole 6 KV/3
1 per module 3AUA0000059813
(female)
2
, 500 V, 32 A,
1 per module 3AXD50000012975
2
2.50 mm
, 12 A,
320 V
Qty
400 mm
1
(15.75 in)
Connecting auxiliary power to
Qty
Ordering code
Dimensions of quick connector for D8T module
Kit code
Ordering code
A-468-8-100
3AUA0000119227
Illustration
on
Instruction code
3AUA0000115013
3AUA0000118667

Advertisement

Table of Contents
loading