4. Parameter Description
Aux Function
GB
GB 34
In CP.36 you can adjust on which parameter the 2nd analog input
REF2 should work (X2.16 / X2.17). During open-loop operation
values 2; 3; 4 and 5 do not have a function !
Adjustment range:
Resolution:
Factory setting:
Factor 1 or CP.10
(see table)
Value Function Analog Input REF2
0
no function
1
adds to the setpoint (has no influence on the Jogging
operation)
2
works as a multiplier for parameter CP.12 (P-factor of the
speed controller)
3
works as a multiplier for parameter CP.13 (I-factor of the
speed controller)
4
works as a multiplier for parameter CP.12 + CP.13 (total gain
of the speed cotnroller)
5
works as a multiplier for parameter CP.9 (torque limit)
0...5
1
0
n [rpm]
U [V]
(REF 2)
0
+10
10 V = CP.10
10 V = gain 1
10 V = gain 1
10 V = gain 1
10 V = gain 1