KEB COMBIVERT F4-F Instruction Manual page 26

Control circuit
Hide thumbs Also See for COMBIVERT F4-F:
Table of Contents

Advertisement

4. Parameter Description
Zero Point Hysteresis REF 1
GB
GB 26
CP.17 adjusts a zero point hysteresis of the setpoint input REF1.
Voltage fluctuations and ripple voltages near the zero point of the
setpoint do not cause the motor to shift.
Adjustment Range:
Resolution:
Factory setting:
This function has a switching hysteresis of 50%. If the analog signal
is larger than the adjusted hysteresis value (CP.17), then the analog
value is active. If the analog signal goes below 50% of the adjusted
hysteresis value (0.5 x CP.17), then the analog setpoint is set at 0.
Analog Signal
CP.17
0,5 x CP.17
Analog Signal
CP.17
0,5 x CP.17
0...10 %
0,1 %
0 %
Preset
Analog Setpoint
Effective
Analog Setpoint
for CP.17 the
following is valid:
^
0...10 % = 0...±1 V
t
t