FOR-A FA-10PS Operation Manuals page 79

Frame synchronizer
Hide thumbs Also See for FA-10PS:
Table of Contents

Advertisement

 Output
Level 1
None
FAN 1/2/3/4 Alarm
FAN 1-4 Alarm
Unit Alarm
DC Power 1/2
DC Power 1-2
Alarm
FS 1-10 Video In
Video In
Reference In
FS 1-10 Audio In
Audio In
Option A-D Audio In
Other
Input Function
*1
DC Power 2 is displayed if the FA-10PS is installed.
*2
Option A-D Audio In are displayed if FA-10AES-BL/UBL/UBLC and/or FA-10ANA-AUD are installed in
respective slots A-D.
The output function varies depending on the Input setting of the port. Refer to the "Input Function
*3
Operation Characteristics of GPI Output" for details.
 Invert
Allows you to select the output logic for Unit Alarm selected under Level 1.
NORM (Normal):
In an Alarm state, output is L (low).
INV (Invert): In an Alarm state, output is H (high).
 Input Function Operation Characteristics of GPI Output
Input setting
All Freeze Frame
All Freeze Odd
All Freeze Even
FS 1-10 Freeze On/Off
All Freeze On/Off
SDI 1-10 By-pass On/Off Outputs when By-pass is set to On for the subject FS.
All By-pass On/Off
Time Code Start
Time Code Stop
Time Code Reset
Time Code Preset
Direct Mode
Take Mode
Take
Destination 1-10
Source 1-10
Salvo 1-100
Event Load Default
Event 1-100
Video Test Signal
FS1-10 Off
Video Test Signal
FS1-10 100% Color Bar
(A FAN is in alarm state.)
(The selected FAN is in alarm state.)
*1
(A DC power is in alarm state.)
*1
(The selected DC power is in alarm state.)
(An alarm has occurred.)
(An video signal is present in the selected FS.)
(A reference signal is present in the selected FS.)
(An audio signal is present in the selected FS.)
*2
(Audio signals are present in the selected option slot.)
*3
(
)
Output Behavior (under Input Function)
Outputs when Freeze Mode is set to Frame for all FSs 1-10.
Outputs when Freeze Mode is set to Odd for all FSs 1-10.
Outputs when Freeze Mode is set to Even for all FSs 1-10.
Outputs when Freeze is set to On for the subject FS.
Outputs when Freeze is set to On for all FSs 1-10.
Outputs when By-pass is set to On for all FSs 1-10.
Outputs when Time Code Starts.
Outputs when Time Code Stops.
No action.
No action.
Outputs when Clean Switch is set to Direct Mode.
Outputs when Clean Switch is set to Take Mode.
Outputs and does not output alternately when a Source is selected
for a Destination in Take Mode so that Clean Switch is in the Take
stand-by state.
Outputs when the subject Destination is selected.
Outputs when the subject Source is selected.
No action.
Outputs and does not output alternately for about 3 seconds when
an Event Load is performed.
Outputs and does not output alternately for about 3 seconds when
an Event Load is performed.
Outputs when Video Test Signal is set to Off for the subject FS.
Outputs when Video Test Signal is set to 100% Color Bar for the
subject FS.