IMPORTANT
Normally set Error Sensing to Normal.
Set to Disable for a specific program or duration when audio output has noise or is
muted.
The FA-1010 fades out audio or resets the delay circuit when a status change (SDI
signal input interruption, signal switchover (by a router, etc.) is detected. Faulty
ancillary data in normal audio signals may also be detected as status changes.
Audio signals with such faulty ancillary data may lead the FA-1010's automatic
correction to improperly process the audio input and produce noise or mute the audio.
Note that disabling the automatic correction can prevent such improper processing,
however, the following functions will also be disabled.
After a signal switchover by router or the recovery of an interrupted SDI signal, delay
settings will lose their accuracy to within ±2 msec max.
Audio signal phases among audio groups will not match.