 To Use the internal power (500 mA, 5 VDC) for GPI outputs
(1) Power OFF the FA-1010.
(2) Remove the FA-1010 top plate by removing 3 screws on the top and 4 screws at each
side. Remove rack-ears if installed.
* Keep the removed screws, 11 in total, in a safe place for use when reinstalling the top
plate.
(3) Change a dipswitch on the FA-10GPI to ON for the outputs. (See the table below.)
In the figure below, "□" indicates the switch position.
For example, when using the internal power for GPI OUT 1, Set Pin 1 in S1 to ON.
GPI card
S1 S2
Dipswitch
S1
S2
(4) Reinstall the top plate and power on the unit.
S1 and S2 dipswitches
Pin no.
Default setting
1
OFF
2
OFF
3
OFF
4
OFF
5
OFF
6
OFF
7
OFF
8
OFF
1
OFF
2
OFF
106
Signal
GPI OUT 1 (output)
GPI OUT 2 (output)
GPI OUT 3 (output)
GPI OUT 4 (output)
GPI OUT 5 (output)
GPI OUT 6 (output)
GPI OUT 7 (output)
GPI OUT 8 (output)
GPI OUT 9 (output)
GPI OUT 10 (output)

Advertisement