11
12
13
Germany_BDEW
7. Set Language
Select "7. Set Language", press "OK". Press "up" or "down" to select the
language and press "OK".
8. Set Time
Select "8.Set Time", press "OK" to enter into time setting interface, the format
of the time is YYYY-MM-DD HH:MM:SS. Press "Up" or "Down" to change the 1
digit, press "OK" to switch to next digit, after inputting the current time, press
"OK".
9. Set EPS (Emergency Power Supply) Mode
9. Set EPS Mode
Description:
PowerBox in the EPS mode can withstand the following load type and
respective rated power:
1, resistive load ≤ 3kW, such as: incandescent, electric water heaters, electric
irons;
2, inductive load ≤ 1kW, such as: hair dryer, coffee machine, refrigerator, air
conditioning, washing machines, vacuum cleaners,
3, capacitive load ≤ 1kW, such as: computers, LED lights etc.
Inductive load and capacitive load will cause at least five time of the rate
impact power to the power. When the energy storage system in the EPS mode
of operation, if the inductive load and capacitive load power is too large
(more than the recommended value system alarm would shows ID27, ID29,
ID30, ID70, ID100 and other system overload protection fault. Disconnect the
capacitive load and inductive load, restart the energy storage system, the
system will return to normal working condition. If you have any questions,
please contact us.