Configuration Of Inputs And Outputs; Erc 113 Inputs And Outputs; Possible Input And Output Connections - Danfoss ERC 113 Reference Manual

Bottle cooler controller
Table of Contents

Advertisement

User manual

Configuration of inputs and outputs

ERC 113 inputs and outputs

Possible input and output
connections
Produced by Danfoss A/S (ADAP-KOOL®) | 2016-07
ERC 113 refrigeration controller
The ERC 113 inputs and outputs are configurable
by the customer. Before getting started it is a
good idea to check if all inputs are configured
correctly and match the sensors attached.
Input and output configuration settings are part
of the assignment menu "ASi".
NOTE: Coded sensors will impact on the number of
possible configurations
Inputs/outputs
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5
Sensor 7
Relay 2
Relay 3
Relay 4
Relay 5
DI (not com)
The table shows the possible input and output connections for the three application setups:
ERC 113 stand-alone, ERC 113 + remote display and ERC 113 + remote spindle.
For instance:
Danfoss supplies only 2-pole defrost sensors, so
input "S3" will most likely be used as a
defrost/evaporator temperature sensor input.
Please contact your local Danfoss representative
for information about default settings.
NOTE: remote display is always connected to the
digital input "Di" an d configured as "buS", whilst
remote spindle is always connected to "S3" and
configured as "rSp"
Stand-alone
With remote display
X
X
X
X
X
X
X
X
DKRCC.ES.RL0.F5.02
With remote spindle
RDI 107
RSP 01
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
5