User manual

Technical specs

Power Supply
100 - 240 VAC (±10%), switch mode power supply
Average 0.7 W
Rated Power
5 Inputs: 4 Analogue & Digital, 1 Digital; user specific assignment
• Air/Evaporator/Condenser
Input
• Light sensor:
Danfoss ECO light sensor
"DO1" (Compressor relay)
"DO4"
Output
"DO5"
"DO6"
Danfoss NTC sensors and Danfoss ECO accessories (300 - 3,000 mm)
Probes
Danfoss PT1000 ohm/0°C
Modular connector system for OEM customers, with optional output screw terminal adapter;
Connectors
Input connector type: Rast2.5 Edge connectors; Output connector type: RAST 5 Standard
Programming
Programming with Danfoss ERC docking station, integrated system
Assembly
Self-drilling screws or plastic quick fasteners
Keypad
Only with RDI 107: 4 buttons (integrated IP65 design), 2 left, 2 right; user programmable
Operating Conditions
0 °C to 55 °C. 93% rH
Storage Conditions
-40 °C to 85 °C, 93% rH
Range of Measurement
-40 °C to 85 °C
Protection
Water and dust protection corresponds to IP31, accessibility of connectors limit rear part rating to IP00
Environmental
Pollution degree II, non-condensing
Resistance to heat & fire Category D (UL94-V0)
EMC category
Category I
Operating Cycles
Compressor relay: more than 175,000 at full load (16A(16A))
R290/R600a end-use applications employing in
accordance to EN/IEC 60335-2-24, annex CC and EN/IEC
60335-2-89, annex BB
Glow wire according to EN/IEC 60335-1
Approvals
IEC/EN 60730
UL60730
NSF
GOST R 60730
IMPORTANT NOTE
The inputs are not galvanic separated and are connected directly to the mains supply!
For that reason, door-switches, sensors as well as the cables must fulfil the reinforced insulation requirements.
Produced by Danfoss A/S (ADAP-KOOL®) | 2016-07
ERC 113 refrigeration controller
UL60730
120 V a.c.: 16 A resistive/FLA16/LRA72
240 V a.c.: 10 A resistive/FLA10/LRA60
8 A resistive, FLA2/LRA12, TV-1
FLA2/LRA12, TV-1
FLA2/LRA12, TV-1
• Door sensor:
all types, user specific
• DP: for remote
communication
These approvals are only valid when using the accessories
approved
DKRCC.ES.RL0.F5.02
• Motion sensor
EN60730
16(16) A
8 A resistive, 2(2) A
8 A resistive, 2(2) A
8 A resistive, 2(2) A
Max 10 A total "DO4-6"