Danfoss ERC 213 Installation Manual

Danfoss ERC 213 Installation Manual

Digital regulator for refrigeration and defrosting, 3 relays
Hide thumbs Also See for ERC 213:

Advertisement

Installation guide
ERC 213
Digital regulator for refrigeration and defrosting, 3 relays.
Dimensions (mm)
83
Assembly
Wiring diagram
Sair
S5
DO1
1
2
~
~
Electrical input
(on the basis of product code)
© Copyright Danfoss | Published by AZ | 2016.04
The ERC 213 is a smart, multipurpose refrigeration controller with temperature and
defrost management, available with 3 relays. The controller has been designed to fulfil
today's requirements for commercial refrigeration applications.
Assembly
DI1
DI2
DO1
DO2
DO3
Sc
DO2 DO3
3L
4N
5
6
7
~
~
61.2
66
Rear mount (clip fixing)
Programming key - EKA 183B
GND TX
15
16
GND
8
9
10
11
Sair
S5 Sc/DI1
Installation guide | ERC 213
71
29
Drilling template
Removal
RX
+5V
17
18
GND
12
13
14
DI2
DKRCE.PI.RL0.O2.02 / 520H11062 | 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ERC 213 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss ERC 213

  • Page 1 ERC 213 Digital regulator for refrigeration and defrosting, 3 relays. The ERC 213 is a smart, multipurpose refrigeration controller with temperature and defrost management, available with 3 relays. The controller has been designed to fulfil today’s requirements for commercial refrigeration applications.
  • Page 2: Technical Features

    Select the type of sensor by pressing UP/DOWN (n5=NTC 5 K, n10=NTC 10 K, Ptc=PTC, Pt1=Pt1000) then SET to confirm. NOTE: all the sensors must by the same type. © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213...
  • Page 3: Menu Structure

    - Press SET to confirm; “o61” is displayed. • Continue to set the following parameters (sensor type “o06”) in the “cFg” menu. © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 3...
  • Page 4: Basic Functions

    DI1 DI2 Sair DI1 DI2 Sair DI1 DI2 S5 Sair 230 V AC 230 V AC 230 V AC DO2 DO3 © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 4...
  • Page 5: Technical Data

    EC (LVD and EMC Directives) Certifications EAC (GHOST) ROHS2.0 HACCP temperature monitoring in compliance with EN134785 Class I if used with sensor AKS 12 © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 5...
  • Page 6 Defrost method no=no defrost, nAt=natural, EL=electrical, gAS=hot gas Defrost stop temperature 50.0 Defrost interval hours N.B.: hidden parameters are greyed out © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 6...
  • Page 7 0.5=steps of 0.5 °C, 1.0=steps of 1.0 °C Relay 1 counter (1 count=100 cycles of operation) N.B.: hidden parameters are greyed out © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 7...
  • Page 8 DI2 input polarity nc=normally closed, no=normally open Invert alarm relay 0=normal, 1=invert relay action Keyboard lock enable N.B.: hidden parameters are greyed out © Copyright Danfoss | Published by AZ | 2016.04 Installation guide | ERC 213 DKRCE.PI.RL0.O2.02 / 520H11062 | 8...
  • Page 9: Safety Standards

    Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed.