Panasonic FP-X0 L14R User Manual page 250

Table of Contents

Advertisement

Name
Boolean
Data compare instructions
16-bit data
ST=
compare
ST<>
(Start)
ST>
ST>=
ST<
ST<=
16-bit data
AN=
compare
(AND)
AN<>
AN>
AN>=
AN<
AN<=
16-bit data
OR=
compare
(OR)
OR<>
OR>
OR>=
OR<
OR<=
: Available,
: Not available,
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Symbol
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1=S2".
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1<S2" or
"S1>S2".
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1>S2".
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1>S2" or
"S1=S2".
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1<S2".
Begins a logic operation by comparing two 16-
bit data in the comparative condition "S1<S2" or
"S1=S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1=S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1<S2" or "S1>S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1>S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1>S2" or "S1=S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1<S2".
Connects a Form A (normally open) contact
serially by comparing two 16-bit data in the
comparative condition "S1<S2" or "S1=S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1=S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1<S2" or "S1>S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1>S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1>S2" or "S1=S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1<S2".
Connects a Form A (normally open) contact in
parallel by comparing two 16-bit data in the
comparative condition "S1<S2" or "S1=S2".
: Not available partially
Description
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp-x0 l40mrFp-x0 l60rFp-x0 l30rFp-x0 l60mr

Table of Contents