The explanation below shows the case that home return is performed with the following conditions; Initial
speed: 1 kHz, Target speed: 5 kHz, Creep speed: 500Hz, Acceleration time: 300 ms, Deceleration time:
500 ms.
Example of timing chart
Data table
Data
Setting item (Unit)
register No.
DT200
Control code
DT202
Initial speed (Hz)
DT204
Target speed (Hz)
DT206
Acceleration time (ms)
DT208
Deceleration time (ms) K500
DT210
Creep speed (Hz)
Deviation counter clear
DT212
signal output time
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Example of sample
program
Home return type 1
Operation mode: Reverse
CW/CCW
H1001 0010
K1000
K5000
K300
K500
K0 (Not output)
Settable range
Set according to the control code
on the next page.
K1 to K20000 (L14/L30 type)
K1 to K50000 (L40/L60 type)
K1 to K20000 (L14/L30 type)
K1 to K50000 (L40/L60 type)
K1 to K32760
K1 to K32760
K1 to K20000 (L14/L30 type)
K1 to K50000 (L40/L60 type)
K0:Not output deviation counter
clear signal
K1 to K200 x 0.5ms(0.5ms~100ms)