7.2.2 Functions Used and Restrictions
The maximum counting speed and pulse output frequency of the high-speed counter vary according to
the number of channels to be used or the combination of used functions. Use the chart below as a guide.
Simplified chart - Maximum counting speed of High-speed counter (For L14 and L30 types)
Combination of high-speed counter
Single-phase
CH0
CH1
CH2
-
-
A
-
A
A
A
A
A
A
A
A
-
-
-
-
-
-
-
-
A
-
-
A
-
-
A
-
A
A
Note) The maximum counting speed may be lower than the above-mentioned values when the target value match
ON/OFF instruction (F166/F167) or an interrupt program is executed simultaneously.
Simplified chart - Maximum counting speed of High-speed counter (For L40 and L60 types)
Combination of high-speed counter
Single-phase
CH0
CH1
CH2
-
-
A
-
A
A
A
A
A
A
A
A
-
-
-
-
-
-
-
-
A
-
-
A
-
-
A
-
A
A
Note) The maximum counting speed may be lower than the above-mentioned values when the target value match
ON/OFF instruction (F166/F167) or an interrupt program is executed simultaneously.
Pulse input/output performance
Independent control
Single-phase
CH0
CH1
-
A
A
A
Note) The L14 type can only use CH0.
補間制御
Single-phase
CH0
A
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Combination with pulse output function (trapezoidal control)
2-phase
Single-
CH3
CH0
CH2
phase
-
-
-
-
-
-
-
-
-
-
-
A
-
-
A
-
A
A
-
-
A
-
A
A
-
-
A
-
-
A
Combination with pulse output function (trapezoidal control)
2-phase
Single-
CH3
CH0
CH2
phase
-
-
-
-
-
-
-
-
-
-
-
A
-
-
A
-
A
A
-
-
A
-
A
A
-
-
A
-
-
A
Max. output frequency (kHz)
For L14/L30 type
20
20
Max. output frequency (kHz)
For L14/L30 type
Not used
Max. counting speed (Frequency kHz)
No pulse output
Pulse output 1 CH
2-
Single-
phase
phase
-
20
20
-
20
20
-
20
20
-
20
20
-
20
-
20
20
20
20
20
20
20
20
20
20
20
19
20
Max. counting speed (Frequency kHz)
No pulse output
Pulse output 1 CH
2-
Single-
phase
phase
-
50
50
-
50
43
-
50
36
-
33
30
-
20
-
20
38
20
39
36
20
39
40
20
40
40
20
40
For L40/L60 type
50
50
For L40/L60 type
50
Pulse output 2 CH
2-
Single-
phase
phase
-
20
-
20
-
14
-
14
-
-
17
-
-
16
17
20
17
20
16
20
14
20
Pulse output 2 CH
2-
Single-
phase
phase
-
36
-
32
-
28
-
24
-
-
20
-
-
16
20
32
20
28
18
36
12
32
A: Available
2-
phase
-
-
-
-
13
12
13
13
12
6
2-
phase
-
-
-
-
16
13
16
16
12
7