OPERATION
How To Operate
Press power switch on level
3
sensor (ON).
1
Set the instrument to the tripod or
smooth surface. Make sure
4
Select the precision mode by
pressing the On-Grade
instrument is roughly level.
Press power switch (ON).
precision switch.
2
Locate the on-grade position
5
"---" by moving the level
sensor up and down.
Height Alert Function
When the instrument system detects a shock, this function informs the
operator of it.
• When the instrument's installation status (height) is sharply changed
by the contact of the operator or the like, this function stops self-
leveling to keep the operation accuracy and informs the operator of the
situation. The three lamps blink at the same time as shown at the right.
• After 1 minute has passed since the self-leveling function was
activated and the laser beam was emitted, this function works.
• The height alert function does not work in the "Manual" mode.
Aligning Direction of Slope
It is possible to set slope only in the X axis direction (refer to "CHECKS
AND ADJUSTMENTS").
[1. Installation of the instrument]
When using the laser to set the slope, the laser must be properly
aligned so the slope axis of the laser beam is parallel to the desired
direction of slope.
The sight on top of the instrument is calibrated to the slope axis of the
laser beam. Follow the steps below to align the laser to the desired
direction of slope:
Establish a target line parallel to desired direction of slope.
1
2
Set up the laser over this line (drop a plumb bob from the tripod
mounting screw).
3
Rough align the instrument to the direction of slope. Make sure it is
properly oriented for the slope to be set.
Using the sight, position the instrument so the sight is centered on
4
the target. (see illustration below)
Target
CHECKS AND ADJUSTMENTS
Checking and adjusting calibration
Horizontal calibration of the laser beam can be checked by the user.
[Checking]
1
Set up a tripod approx. 50m (160ft) from a wall. Mount the
instrument on the tripod, facing the X1 side toward the wall.
Turn the instrument on and allow self-leveling to complete.
2
3
Put the level sensor in fine detection mode by pressing the On-
Grade precision switch.
4
By using the level sensor, mark the center position of laser beam
on the wall. (X1)
Turn off the instrument.
5
Loosen the tripod screw, rotate the instrument 180 degrees and
re-secure it on the tripod. The X2 side of the instrument faces
toward the wall.
When rotating the instrument, avoid changing the height.
Turn the unit on again and allow self-leveling to complete.
6
7
By using the level sensor, mark the center position of laser beam
on the wall. (X2)
8
If the difference value of marked two laser beam heights
(difference value of X1 and X2) are less than 5mm, adjustments
are not needed.
The difference value is greater than 5mm, adjust the instrument
as described in right.*
9
Check the Y side as the same way.
* If the difference value is greater than 40mm (±90"), it exceeds the
adjustment range. Please contact your local dealer.
Checking cone error
Cone error
Datum
Wall A
Wall B Wall A
position

ERROR CODE

Use the table below to determine operation errors indicated by blinking lamps on the control panel.
(For the lamp indication, refer to "Lamp position".)
If corrective action listed does not correct error, please contact your local dealer.
Lamp Indication
Error Code
Lamp B, C and D blink in turn Self-leveling range error Correct tilt of the instrument until it less than 5 degrees.
Lamp A lights
Battery power error
Lamp B, C and D blink
Height alert error
simultaneously
Lamp D blinks quickly
Calibration error
Lamp E lights
Checking and adjusting
Lamp B, C and D blink in turn
calibration error
Lamp A, B, C and D blink
Internal error
simultaneously
Please see the following website for contact addresses.
GLOBAL GATEWAY http://global.topcon.com/
Mark the position of On-Grade index.
6
(Top of the level sensor is 40mm [1 9/16"]
from index for offset marking.)
Shock is given to the instrument.
[2. Setting slope]
Operating procedure
(Setting slope)
1 Press Power switch ON.
You can set the slope after self-leveling is
completed.
2 Press one of Slope keys once. The laser
beam keeps sloping in the direction of the
pressed key.
3 Press the Slope key again. The laser beam
stops sloping.
(Unless you press the Slope key again, the
laser beam is set horizontally.)
4 Press the Slope key to adjust the slope.
How long you press the Slope key can
change the laser beam sloping speed. The
blinking speed of the lamp provides a visual
indication of the beam movement speed.
5 Press Power switch OFF to cancel the
slope setting.
• After setting the slope, the self-leveling does not function in the X axis direction.
level sensor
X1 Laser beam
Approx. 50m
X2 Laser beam
Approx. 50m
Y2
X2
Handle
Y1
Control panel
Perform the following check after completing horizontal calibration procedure.
Approx. 40m
[Checking]
Set up the laser centered between two walls approximately 40m (131ft) apart. Orient the instrument so one axis, either X or Y, is facing the walls.
1
Locate and mark the position of the rotating laser beam on both walls using the level sensor.
2
3
Turn off the instrument and move the instrument closer to wall A (1m to 2m /3 ft to 6 ft). Do not change the axis orientation of the instrument. Turn the instrument on.
Again locate and mark the position of the rotating laser beam on both walls using the level sensor.
4
Wall B
5
Measure the distance between the first and second marks on each wall. If the difference between each set of marks is less than 4mm (5/32 of an inch), no error exists.
* If the difference value is greater than 4mm (5/32 inch), contact your local dealer.
Corrective Action
Replace the four alkaline dry cell batteries with new ones
at a time or charge the battery pack.
Turn power off, rough level the instrument, then turn
power on again. Check height of laser beam as it may
have changed.
Repeat calibration procedure. If error repeats contact
your local dealer.
Push the slope key of the opposite side, and align slope.
Turn power off, then on again in stable locations. If error
repeats contact your local dealer.
http://www.topcon.co.jp
© 2017 TOPCON CORPORATION
ALL RIGHTS RESERVED
LS-80L Indicator
Height alert warning of rotating laser*1
A flash and a buzzer sound signifies
that the height alert function of rotating
laser is operating.
Rotating laser battery warning*2
A flash shows that the rotating laser
power is low.
Note: The warning displays *1 and *2 are the functions that the level sensor
detects alarm signal from the rotating laser.
The level sensor can be canceled the alarm detection from the rotating laser.
To be canceled the detection; Press the power switch while pressing the
buzzer sound switch when powering on.
Height alert status
[How to reset]
1
2
3
4
The three lamps blink at the same time
and the rotary head rotates at low speed.
Key
operation
(Refer to the right illustration)
Power switch
During self-leveling: Lamp B blinks.
After self-leveling is completed.: Lamp B lights.
After self-leveling
is completed.
Lamp E blinks quickly.
Slope key
Slope key
Lamp E lights.
Slope key
When Slope key is not pressed: Lamp E lights.
Slope key
Press for a shorter time Blinks slowly
Press for a longer time
Power switch
All lamps are OFF.
[To calibrate the X axis]
Wall
Face the X1 side of the instrument toward a wall, press the Power switch while pressing the height alert OFF key. Then the
1
height alert OFF lamp will light, and manual mode ON lamp will blink. (X axis is selected.)
X1
2
Press the height alert OFF key to calibrate the X axis. The manual mode ON lamp will light. When self-leveling finishes, the
laser beam will emit.
3
Using the level sensor, mark the on-grade height of laser beam on a wall.
Rotate the instrument 180 degrees to face X2 side toward a wall.
4
Laser point of X1
In the same way as step 3, mark the on-grade height of laser beam on a wall.
5
6
Press the slope key to make adjustment so that the laser beam height may be at the center between the positions of Step 3 and Step 5.
Press the height alert OFF key to memorize the new laser beam calibration. The height alert OFF lamp will blink. Power will
7
shut off automatically when the calibration memorization is complete.
The X axis adjustment is completed now.
[To calibrate the Y axis]
X1
Face the Y1 side of the instrument (Control panel side) toward a wall, press the Power switch while pressing the height alert
1
OFF key. Then the height alert OFF lamp will light, and manual mode ON lamp will blink. (X axis is selected.)
Press the right Slope key once again. The self-leveling lamp will blink. (Y axis is selected.)
2
X2
3
Press the height alert OFF key to calibrate the Y axis. The self-leveling lamp will light.
Using the level sensor, mark the on-grade height of laser beam on a wall.
4
Laser point of X2
Rotate the instrument 180 degrees to face Y2 side toward a wall.
5
6
In the same way as step 4, mark the on-grade height of laser beam on a wall.
Press the slope key to make adjustment so that the laser beam height may be at the center between the positions of Step 4 and Step 6.
7
8
Press the height alert OFF key to memorize the new laser beam calibration. The height alert OFF lamp will blink. Power will
shut off automatically when the calibration memorization is complete.
The Y axis adjustment is completed now.
X1
If the height alert OFF lamp blinks quickly and the power is not automatically turned off when pressing the height alert OFF key to
memorize the height, the height exceeds the adjustment range. Please contact your local dealer.
To discontinue calibration the instrument, press the Power switch.

SPECIFICATIONS

RL-H5A
Laser source:
Laser diode (Visible, 635 nm)
CDRH (FDA) Class IIIa, IEC Class 3R
Laser output:
2.4 mW
Self-leveling range:
±5°
Accuracy:
±10"
Manual slope settable range:
±5° (When the instrument is installed on the 0° surface)
The slope range is increased or decreased
according to the tilt of the surface on which the
instrument is installed.
Rotational speeds:
600 r.p.m
Operating range:
Diameter Approx. 2 to 800 m (When using LS-80L)
Power source/Operating time at 20°C (68°F):
4xD size dry cell batteries (alkaline) /100 hours
Ni-MH battery pack BT-79Q (7000mAh) /60 hours
Charging time:
about 13 hours (Using with AD-17B/C/D/E)
Charging temperature range: 10 to 40°C (50 to 104°F)
Dust and water resistance:
IP66 (IEC60529: 2001)
Operating temperature:
-20 to 50°C (-4 to 122°F)
Storable temperature range:
-30 to 60°C (-22 to 140°F)
Remote warning display:
RL-H5A height alert warning(Warning is displayed
on the indicator of LS-80L.)
RL-H5A battery warning (Warning is displayed on
the indicator of LS-80L.)
Size:
172 (L) x 211 (W) x 205 (H) mm
Laser beam height:
171.8 mm (Height from the instrument's bottom
surface to the center point of laser beam)
Weight
Dry battery type:
2.3 kg (5.1 lbs) (with dry cell batteries)
Rechargeable battery type: 2.5 kg (5.5 lbs) (with BT-79Q)
Tripod screw:
5"/8X11 threads for surveying instrument
High precision mode
Normal precision mode
Higher than datum position
(Buzzer sound: High frequent beep sound)
Move the sensor downward.
Datum position
(Buzzer sound: Continuous beep sound)
Lower than datum position
(Buzzer sound: Low frequent beep sound)
Move the sensor upward.
Battery remaining display
Turn off the power switch.
Check whether the instrument is installed
correctly.
Turn on the power switch. Self-leveling starts
B: Power lamp /
again. After self-leveling is finished, the laser
beam is emitted.
C: Manual mode ON
Make sure that the laser beam is set at the
correct height. Then, restart the operation.
D: Height alert OFF
Lamp display
How to set the slope before the power is OFF again
To set the slope before the power is OFF again, turn on
1
the Power switch as pressing either right or left of the
Slope keys. The slope is kept and you can adjust the
slope in the same way as Step 4.
(When the Power switch is ON without the Slope key
pressed, the laser beam will return to level.)
• When you set the "Manual" mode to ON after setting
the slope, the beam is fixed at the set slope position.
At this time the Slope key does not function.
Lamp E
Beam movement
For information about Manual mode ON/OFF, refer to
Moves slowly
"NOMENCLATURE AND FUNCTIONS".
Blinks quickly
Moves quickly
• Check the beam often during slope use for slope
accuracy. Check instrument calibration periodically.
BT-79Q (Ni-MH rechargeable battery)
Nominal voltage:
Capacity:
Size:
Weight:
AD-17B/C/D/E
Input voltage:
Output voltage:
Charging time:
Charging temperature range: 10 to 40°C (50 to 104°F)
Storage temperature range:
Size (excluding cable)/ Weight
LS-80L
Beam detection width:
On-Grade precision:
Beam detection indication:
Power source:
Operating time (at 20°C):
Automatic shutoff:
Dust and water resistance:
Operating temperature:
Storage temperature:
Size:
Weight:
Detective Range
(1) Battery is sufficient.
(2) The power is low, but
laser is still usable.
(3) Dead battery.
Replace the dry battery
with new one.
Lamp Position
E: Slope lamp
Slope key
A: Battery power
lamp
Self-leveling lamp
lamp
lamp
Height alert
OFF key
Power switch
Manual mode ON key
4.8V
7,000mAh
104(W) x 127(D) x 37(H) mm
690 g
100 to 240 V AC, 50 to 60 Hz, 0.6 A
DC 9 V/2.0 MAX 18 W
about 13 hours
-20 to 70°C (-4 to 158°F)
AD-17B:
45(W) x 83(D) x 54(H) mm /133 g
AD-17C:
45(W) x 83(D) x 70(H) mm /137 g
AD-17D:
45(W) x 83(D) x 59(H) mm /135 g
AD-17E:
45(W) x 83(D) x 62(H) mm /140 g
50 mm (2.0 in)
High: ±1 mm (±0.04 in)
Normal: ±2 mm (±0.08 in)
Liquid crystal (both sides) and buzzer
2xAA size dry cell batteries
about 120 hours (Using alkaline
manganese dry cell batteries)
after 30 minutes (without beam
detection)
IP66 (IEC60529: 2001)
-20 to 50°C (-4 to 122°F)
-30 to 60°C (-22 to 140°F)
146(L)x76(W)x26(H) mm
0.19 kg (0.41 lbs) (with dry cell batteries)

Hide quick links: