Factory Reset - Socket SocketScan S700 User Manual

Bluetooth wireless technology barcode scanner
Hide thumbs Also See for SocketScan S700:
Table of Contents

Advertisement

Factory Reset will restore the SocketScan to Factory Default settings
(configured as shipped).
Scan this barcode
Reset (button) sequence:
1. Power ON the reader.
2. Press and hold the scan button.
3. Tap the power button once while continuing to press the trigger.
4. Keep holding the scan button until you hear a beep
(about15 seconds).
When you release the scan button you will hear 5 confirmation beeps.
The next time you power on the S700, it will take longer to start up. After
it finishes powering on, it will have factory default settings (HID mode).
Note: If you follow this sequence but release the scan button too early,
the Factory Reset will fail.

FACTORY RESET

Quickly press and release
the power button
1
2
or
follow the Factory
21

Advertisement

Table of Contents
loading

Table of Contents