Image Stabilization Timeout; Timeout Between Decodes - Newland NLS-FM3051-2X User Manual

Nls-fm305x-2x series fixed mount barcode scanner
Table of Contents

Advertisement

Enter Setup

Image Stabilization Timeout

This parameter defines the amount of time that the scanner waits for the image to stabilize to a point that
it can be decoded with more accuracy. It is programmable in 100ms increments from 0ms to 1,600ms.
The default setting is 100ms. To learn how to program this parameter, see Appendix 5.
Image Stabilization Timeout

Timeout between Decodes

This parameter sets the timeout between decode sessions. When a decode session ends, next session
will not happen until the timeout between decodes expires. It is programmable in 1ms increments from 0ms
to 65,535ms. The default setting is 200ms. To learn how to program this parameter, see Appendix 5.
Timeout between Decodes
** Exit Setup