INSTALLING THE OPTIONAL PUMP
1. Prepare to Mount the Pump (PBA-G)
Identify a space to place the pump. The pump can be
placed on the floor for convenience, preferably in close
proximity to the main assembly. This will ensure that the
tubing is kept to a minimum and is neatly arranged.
The pump may be mounted as well, however, do not
mount the pump with screws until the tubing is
completed.
In the main assembly, the sediment pre-filter is connected
to the feed assembly and to the GAC pre-filters, such that
the flow is indicated
coming from the feed
water
assembly
to
sediment pre-filter to
the GAC pre-filters.
Remove the tubing that
makes the connection
between
the
feed
assembly
and
the
sediment pre-filter; the
p u m p
w i l l
b e
connected in between
these
(figure
D1).