You can obtain specifics about your water supply from
either your local water department or your local Author-
ized Aquathin Dealer. If the parameters of your water do
not fall within the specified ranges as noted above, please
contact your local Aquathin Dealer for further options.
Production is rated at optimum temperature of 70° F, 60
PSI, and 500 ppm TDS. Actual production will vary de-
pending on local temperature, pressure, and TDS level.
Low tap water pressure will reduce the volume and qual-
ity of the water produced by your system. In low pressure
situations (<40 PSI) RO/DI values cannot be assured.
The addition of a booster pump (PBA-G) is strongly rec-
ommended.
ALWAYS USE COLD WATER—hot water will damage
the TFC membrane.
The unit must not be allowed to freeze. Freezing water
will expand inside the modules—damaging the mem-
brane and potentially rupturing the filter housings. Dam-
age of this type will void the warranty.
This system has been tested and certified by IAPMO
R&T according to NSF/ANSI 58 and WQA S-300 for
reduction of TDS. The concentration of TDS in water
entering the system was reduced to less than or equal to
the permissible limit for water leaving the system, as
specified in NSF/ANSI 58 and WQA S-300. Testing was
performed under standard laboratory conditions. Follow
installation procedures and scheduled maintenance for
optimum performance.